江阴美鸿光伏应用材料有限公司

SMG4 suitable for scale ground mounting system,meet with different fix requests by perfect connection with spiral pile.  

Technical Parametres

Fix Position Ground Wind Load60m/s
Fix Base Spiral pileSnow Load1.6KN/M²
Fix Angle 5-60°Module ArrangeVertical & Horizontal
Suitable ModuleFrame or FramelessMaterialQ235B(hot-dip galvanizing)
FastenerCabon Steel (Dacromet)ColorSilver
AccessoriesQ235B(hot-dip galvanizing)Quantity Warranty 10 years

Product Accessories 

                          

    end clamp                  Middle clamo                  Triangular connector       Square pipe pile  connection 

                   
 L-type screw pile connector   upright column          side support                   C74 longitudinal beam 

         
C62beam                   C62beam connect       C41 longitudinal beam 

Fix procedure

1.Position according to the designing sheet 


2.Connect L base with screw pile connector square pile and screw pile with M16*200 screw, finish all the upright column connector.

   

3.After abovementioned step, fasten the front column and rear column with column connector with M12*75 screw.


4.After abovementioned step, connect triangular connector and upright column with M12*75,  connect C41*74*2.5 and triangular connector with hexagon M10*30

     

5.Connect triangular connector with upright column,put the support throuht triangular connection and connect with front column with M12*75, with support and rear column through it 

          


6.Put beam C62 on longitudinal beam C74

           

7.Put Rail C41 on beam C62

    


8.Fasten the angle steel on the rear column with M10*80 screw   

  

9.Fasten the module with middle and end clamps 


Engineering Case